- Overview
- Instruments
- PC Requirements
- Library
Overview
- Description
- Features
Line Sweep Tools allows users to quickly and efficiently process captured line sweeps, as well as PIM measurements. In addition, it has some capability for handling common S parameter measurements as well as transmission measurements. Marker and Limit Line Presets Marker presets are invaluable when reviewing large numbers of line sweeps. LST has 7 sets of marker presets. Quick Names |
Automated Report Generation
LST has report generation for both PIM traces and Line Sweeps. Producing industry standard reports, in PDF format, LST can also create files in the industry standard DAT format.
Instrument CompatibilityLST is compatible with a wide range of Anritsu handheld instruments. For specifics, please see the “Instruments Supported” tab.
Line Sweep Tools —The Cable and Antenna Analyzer Software Tool Set
Anritsu Line Sweep Tools (LST) is the latest generation of Handheld Software Tools, an industry standard. This PC based post-processing software efficiently manipulates line sweep and PIM traces for reporting purposes.
Line Sweep Tools enables users to quickly:
- Collect traces from the instruments
- Verify that the traces are correct using markers and limit lines
- Report results in industry accepted PDF and/or DAT file format
Instruments
Line Sweep Tools works with traces taken from Anritsu's line of Handheld RF Instruments, and is focused on the measurements needed for Antenna and Cable service. Examples include Return Loss, Distance to Fault, PIM measurements, and even some S11 measurements.
Line Sweep Tools is compatible with the traces produced by the older Site Masters, in some cases going all the way back to A series Site Masters such as the S331A.
Instruments Supported | ||||||
Product Family | Instrument | Cable and Antenna Analyzer Mode Measurements | Transmission Measurement | Two Port Cable Loss or Two Port Gain | Passive Intermodulation (PIM) Measurements | Smith Chart |
Site Master | S113B | X | X* | |||
S114B | X | X* | ||||
S251B | X | X* | ||||
S331B | X | X* | ||||
S332B | X | X* | ||||
S113C | X | X* | ||||
S114C | X | X* | ||||
S251C | X | X* | ||||
S331C | X | X* | ||||
S332C | X | X* | ||||
S810C | X | X* | ||||
S820C | X | X* | ||||
S311D | X | X | X* | |||
S312D | X | X | X* | |||
S331D | X | X | X* | |||
S332D | X | X | X* | |||
S325D | X | X* | ||||
S810D | X | X | X* | |||
S820D | X | X | X* | |||
S820E | X | X | X | X | ||
S331E | X | X | X* | |||
S332E | X | X | X | X | ||
S361E | X | X | X | |||
S362E | X | X | X | X | ||
S331L | X | X* | ||||
S331P | X | X | X* | |||
PIM Master | MW82119A | X | ||||
MW82119B | X | |||||
Spectrum Master Supporting PIM Analyzers MW8208A | MS2711E | X | ||||
MS2712E | X | |||||
MS2713E | X | |||||
MS2721B | X | |||||
MS2722C | X | |||||
MS2723C | X | |||||
MS2724C | X | |||||
MS2725C | X | |||||
MS2726C | X | |||||
Cell Master | MT8212A | X | X* | |||
MT8212B | X | X* | ||||
MT8212E | X | X | X | X | ||
MT8213E | X | X | X | X | ||
BTS Master | MT8222A | X | X | X | ||
MT8221B | X | X | X | X | ||
MT8222B | X | X | X | X | ||
MT8220T | X | X | X | X |
Instruments Supported | |||||
Product Family | Instrument | Common Field Mode Measurements | Insertion Loss | Smith Chart | Common Vector Network Analyzer Measurements |
LMR Master | S412D | X | X* | ||
S412E | X | X | X | X | |
VNA Master | MS2024A | X | X | X | |
MS2026A | X | X | X | ||
MS2034A | X | X | X | ||
MS2036A | X | X | X | ||
MS2024B | X | X | X | X | |
MS2025B | X | X | X | X | |
MS2026B | X | X | |||
MS2028B | X | X | |||
MS2034B | X | X | X | X | |
MS2035B | X | X | X | X | |
MS2026C | X | X | |||
MS2028C | X | X | |||
MS2036C | X | X | |||
MS2038C | X | X |
Notes:
- Line Sweep Tools can also make use of Hand Held Software Tool files captured by the discontinued "A" series Site Masters.
- X* = For these instruments, the Smith Chart is created by LST from other traces.
Common Field Mode Measurements
- Return Loss (RL)
- Voltage Standing Wave Ration (VSWR)
- Distance to Fault, Return Loss (DTF-RL)
- Distance to Fault, VSWR (DTF-VSWR)
- Cable Loss (CL)
- Smith Chart
- Phase
Common Vector Network Analyzer Measurements
- LogMag vs. Frequency – S11, S12, S22
- LogMag vs. Frequency – S21
- LogMag vs. Distance – S11, S22
- SWR vs. Frequency – S11, S22
- SWR vs. Distance – S11
- Phase vs. Frequency – S11, S12, S21, S22
- Phase vs. Distance – S11
- LogMag/2 vs. Frequency – S11
- Real Impedance vs. Frequency – S11
- Imaginary Impedance vs. Frequency – S11
- Smith Chart vs. Frequency – S11, S12, S21, S22
- Group Delay – S11, S12, S21
- Vector Voltmeter
Related Links
PC Requirements
PC Requirements
Anritsu's software tools runs on computers using Windows
operating systems, specifically:
- Windows XP, Service Pack 2 or higher
- Windows Vista (32 bit or 64 bit)
- Windows 7 (32 bit or 64 bit)
- Windows 8 (32 bit or 64 bit)
- Windows 10 (32 bit or 64 bit)
In addition, the PC must have at least:
- 1 GB of RAM
- 1 GB of available hard disk space
Related Links
Library
- Quick Start Guide
Quick Start Guide
Release Date
Anritsu Tool Box Quick Start Guide 3/7/2018 - User Guide
User Guide
Release Date
Line Sweep Tools User Guide 2/27/2018 - Instruction Sheet
Instruction Sheet
Release Date
Line Sweep Tools FAQ Instruction Sheet 10/20/2014